M7220 Serial USB (COM3) Driver Download



  1. These drivers are static examples detailed in Application Note 197: The Serial Communications Guide for the CP210x. The CP210x Manufacturing DLL and Runtime DLL have been updated and must be used with v 6.0 and later of the CP210x Windows VCP Driver. Application Note Software downloads affected are AN144SW.zip, AN205SW.zip and AN223SW.zip.
  2. USB-SERIAL CH340 (COM3) - Driver Download. Vendor:. Product: USB-SERIAL CH340 (COM3). Hardware Class: Ports. Search For More Drivers.: Go! Windows 10 32-Bit Driver.
  3. Com Port Driver PL2303 for Windows 8.1 (64-bit) - ThinkCentre M93, M93p, M92, M92p, M72e. Sweden Switzerland Taiwan Region Thailand Turkey Ukraine United Arab Emirates United Kingdom United States of America Uruguay US Downloads Venezuela Vietnam.

How Do I Emulate a COM/Serial Port Over USB? Supported DCS products, refer to the USB CDC Driver for Windows page or the user guide of the scanner. If using DS3578 or LS3578, Bluetooth FIPs cradle part # STB3578-CF007WR must be used. Resolution / Answer. To emulate a COM port over a USB connection, please follow these steps 1. Serial Port To Usb free download - HiSerial.sys Serial Port Driver, Port Detective, Serial Key Generator, and many more programs.

The terms of the software license agreement included with any software you download will control your use of the software.

INTEL SOFTWARE LICENSE AGREEMENT

IMPORTANT - READ BEFORE COPYING, INSTALLING OR USING.

Do not use or load this software and any associated materials (collectively,

the 'Software') until you have carefully read the following terms and

conditions. By loading or using the Software, you agree to the terms of this

Agreement. If you do not wish to so agree, do not install or use the Software.

LICENSES: Please Note:

- If you are a network administrator, the 'Site License' below shall

apply to you.

- If you are an end user, the 'Single User License' shall apply to you.

- If you are an original equipment manufacturer (OEM), the 'OEM License'

shall apply to you.

SITE LICENSE. You may copy the Software onto your organization's computers

for your organization's use, and you may make a reasonable number of

back-up copies of the Software, subject to these conditions:

M7220 Serial Usb (com3) Driver Downloads

1. This Software is licensed for use only in conjunction with Intel

component products. Use of the Software in conjunction with non-Intel

component products is not licensed hereunder.

2. You may not copy, modify, rent, sell, distribute or transfer any part

of the Software except as provided in this Agreement, and you agree to

prevent unauthorized copying of the Software.

3. You may not reverse engineer, decompile, or disassemble the Software.

4. You may not sublicense or permit simultaneous use of the Software by

more than one user.

5. The Software may include portions offered on terms in addition to those

set out here, as set out in a license accompanying those portions.

SINGLE USER LICENSE. You may copy the Software onto a single computer for

your personal, noncommercial use, and you may make one back-up copy of the

Software, subject to these conditions:

1. This Software is licensed for use only in conjunction with Intel

component products. Use of the Software in conjunction with non-Intel

component products is not licensed hereunder.

2. You may not copy, modify, rent, sell, distribute or transfer any part

of the Software except as provided in this Agreement, and you agree to

prevent unauthorized copying of the Software.

3. You may not reverse engineer, decompile, or disassemble the Software.

M7220 Serial Usb (com3) Driver Download 64-bit

4. You may not sublicense or permit simultaneous use of the Software by

more than one user.

5. The Software may include portions offered on terms in addition to those

set out here, as set out in a license accompanying those portions.

OEM LICENSE: You may reproduce and distribute the Software only as an

M7220 serial usb (com3) driver downloads

integral part of or incorporated in Your product or as a standalone

Software maintenance update for existing end users of Your products,

excluding any other standalone products, subject to these conditions:

Usb

1. This Software is licensed for use only in conjunction with Intel

component products. Use of the Software in conjunction with non-Intel

(COM3)

component products is not licensed hereunder.

2. You may not copy, modify, rent, sell, distribute or transfer any part

of the Software except as provided in this Agreement, and you agree to

prevent unauthorized copying of the Software.

3. You may not reverse engineer, decompile, or disassemble the Software.

4. You may only distribute the Software to your customers pursuant to a

written license agreement. Such license agreement may be a 'break-the-

seal' license agreement. At a minimum such license shall safeguard

Intel's ownership rights to the Software.

5. The Software may include portions offered on terms in addition to those

set out here, as set out in a license accompanying those portions.

NO OTHER RIGHTS. No rights or licenses are granted by Intel to You, expressly

or by implication, with respect to any proprietary information or patent,

copyright, mask work, trademark, trade secret, or other intellectual property

right owned or controlled by Intel, except as expressly provided in this

Serial

Agreement.

OWNERSHIP OF SOFTWARE AND COPYRIGHTS. Title to all copies of the Software

remains with Intel or its suppliers. The Software is copyrighted and

protected by the laws of the United States and other countries, and

international treaty provisions. You may not remove any copyright notices

from the Software. Intel may make changes to the Software, or to items

referenced therein, at any time without notice, but is not obligated to

support or update the Software. Except as otherwise expressly provided, Intel

grants no express or implied right under Intel patents, copyrights,

trademarks, or other intellectual property rights. You may transfer the

Software only if the recipient agrees to be fully bound by these terms and if

you retain no copies of the Software.

LIMITED MEDIA WARRANTY. If the Software has been delivered by Intel on

physical media, Intel warrants the media to be free from material physical

defects for a period of ninety days after delivery by Intel. If such a defect

is found, return the media to Intel for replacement or alternate delivery of

the Software as Intel may select.

EXCLUSION OF OTHER WARRANTIES. EXCEPT AS PROVIDED ABOVE, THE SOFTWARE IS

PROVIDED 'AS IS' WITHOUT ANY EXPRESS OR IMPLIED WARRANTY OF ANY KIND

INCLUDING WARRANTIES OF MERCHANTABILITY, NONINFRINGEMENT, OR FITNESS FOR A

PARTICULAR PURPOSE. Intel does not warrant or assume responsibility for the

accuracy or completeness of any information, text, graphics, links or other

M7220 Serial USB (COM3) Driver Download

items contained within the Software.

Download driver modem aiko 76eDescent 2 vertigo download free. Mahabharat ailo 35 download skype. Download serial number game house. Acer 76e driver download windows 7. Fast Download driver modem aiko 76e Elicenser activation code modem aiko 76e 3 download.Download croto chip percuma definition.

LIMITATION OF LIABILITY. IN NO EVENT SHALL INTEL OR ITS SUPPLIERS BE LIABLE

FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, LOST PROFITS,

BUSINESS INTERRUPTION, OR LOST INFORMATION) ARISING OUT OF THE USE OF OR

INABILITY TO USE THE SOFTWARE, EVEN IF INTEL HAS BEEN ADVISED OF THE

POSSIBILITY OF SUCH DAMAGES. SOME JURISDICTIONS PROHIBIT EXCLUSION OR

LIMITATION OF LIABILITY FOR IMPLIED WARRANTIES OR CONSEQUENTIAL OR INCIDENTAL

DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. YOU MAY ALSO HAVE

M7220 Serial Usb (com3) Driver Download Windows 10

OTHER LEGAL RIGHTS THAT VARY FROM JURISDICTION TO JURISDICTION.

TERMINATION OF THIS AGREEMENT. Intel may terminate this Agreement at any time

if you violate its terms. Upon termination, you will immediately destroy the

Software or return all copies of the Software to Intel.

APPLICABLE LAWS. Claims arising under this Agreement shall be governed by the

laws of California, excluding its principles of conflict of laws and the

United Nations Convention on Contracts for the Sale of Goods. You may not

export the Software in violation of applicable export laws and regulations.

Intel is not obligated under any other agreements unless they are in writing

and signed by an authorized representative of Intel.

GOVERNMENT RESTRICTED RIGHTS. The Software is provided with 'RESTRICTED

RIGHTS.' Use, duplication, or disclosure by the Government is subject to

restrictions as set forth in FAR52.227-14 and DFAR252.227-7013 et seq. or its

successor. Use of the Software by the Government constitutes acknowledgment

of Intel's proprietary rights therein. Contractor or Manufacturer is Intel

2200 Mission College Blvd., Santa Clara, CA 95052.

USB BitScopes require the installation of a driver when first used with Windows.

This usually happens automatically when you first connect your BitScope.

However you may need to install the driver manually if:

  • Your PC is not connected to the Internet,
  • You are using Windows XP or Vista (not recommended!),
  • You are using Windows 7 Starter or Home Edition,
  • The automated windows installer fails for some other reason.

You may then need to configure the software to use the correct COM Port.

To optimize performance in Windows we recommend reducing the driver latency.

For more information about all this, read below or click through these links:

  • Automatic Driver Installation which is the usual case for most people.
  • Manual Driver Installation if automatic installation did not work for you!
  • Which COM Port was assigned by Windows when you installed the driver?
  • Choose the correct COM Port if it's not already automatically selected.
  • Use Windows Device Manager if Windows prevents you accessing devices.
  • Reduce Driver Device Latency to improve your BitScope performance.
  • Troubleshooting USB if your BitScope still cannot not connect to your PC.

Of course, email us anytime at support@bitscope.com if you need assistance!

In most cases, there is nothing to do, just plug in the BitScope.

The following pop-up should appear at the bottom right of the desktop.

Its appearance may differ a little depending on the edition and version of Windows 7 or 8 you are using (The remainder of this tutorial uses Windows 7) To observe progress click the pop-up dialog to reveal:

When the installation completes you will see:

Take note of the COM Port identifier (COM3 in this example) as you may need it later.

If the automatic installer failed you may see this:

In this case you will need to UNPLUG YOUR BITSCOPE and download the driver:

and when complete, run it:

You will be asked to extract it:

and then install it:

which may take some time to complete:

Serial

When the installation is complete you may see this dialog:

Take note of the COM Port identifier (COM3 in this example) as you may need it later.

Sometimes it's necessary to learn the device properties for a USB BitScope.

The most common reason is to see the COM Port number Windows has assigned when the driver was installed (if you forgot to take note of it at the time).

Select Devices and Printers:

Find the BitScope (it should be listed) and select properties:

and then select the Hardware Tab:

Here you can see the COM Port number (COM3 in this example).

If only one USB BitScope is connected choosing the COM Port is unecessary

All BitScope Applicationsautomatically connect with that one BitScope.

However, if more than one BitScope is connected or there are other FTDI COM Port devices connected to your PC (e.g. a serial mouse), you may need to configure the software to use the correct COM Port.

This can be done with most BitScope Apps. With DSO click SETUP:

and choose the correct COM Port (COM3 in this example) and Click OK:

Doing this with one BitScope Application sets the port used for all applications so you won't need to do this again.

In the case of DSO, click POWER to start the application:

Note that COM3 is reported at the bottom of the application. If the selected COM Port does not appear here, you are not connected to your BitScope (troubleshooting).

Windows may throw up a roadblock when trying to view the COM port or adjust the device properties when accessed the more direct way.

In this case you may need to use Device Manager to access the device properties.

First select the Computer Properties:

and then choose the Device Manager:

From the Device Manager, find the USB Serial Port:

(which is COM3 in this example) and right-click to open the device properties:

BitScope prefers the shortest USB latency to achieve the highest performance.

Unfortunately Windows 7 & 8 install the driver with a long latency by default.

Reduce the latency value to significantly improve performance when talking to a USB BitScope with Windows 7 or 8.

After installing the USB driver, select the device properties and then choose the properties for the COM port assigned to your BitScope (COM3 in this example):

Select the Port Settings tab and click Advanced:

At this point you may be told:

If so, you will need to access the Port Settings tab via the Device Manager instead (this is due to a bug in many editions of Windows 7 and 8).

Whether you've used Device Manager or this route you should then see:

Change the default latency (16 ms) to 1 ms:

Click OK to accept the new value.

You may then need to restart Windows for the new value to take effect.

If you have successfully installed the driver but still you cannot connect:

  • Be sure to download and use the latest versions of BitScope Software.
  • Temporarily disconnect any other USB Serial devices from your PC.
  • Check which COM port Windows assigned when you installed the driver.
  • Be sure to chose the same COM portvia the BitScope Software setup dialog.
  • Check your BitScope is powered on (the red LED on the back should be lit).
  • Confirm your power supply is good (for externally powered BitScope models).
  • Try connecting directly your PC's USB port if you're using a USB Hub.
  • Connect via a different USB port possibly using a different USB cable.
  • Try a different PC and/or other software to rule out PC based problems.

If you can connect but there are still problems:

  • If BitScope DSO reports OFFLINEcheck the selected COM port is correct.
  • If BitScope DSO reports SYDNEYcheck the selected COM port is correct.
  • If your BitScope seems to be slow to respond reduce the driver latency.
  • If it's slow to connect make sure the correct COM port is listed first.

If you still have problems, especially if you are upgrading from older software versions, the configuration files used by the application software may have been corrupted.

The file most likely to cause problems (if corrupt) is the probe file.

The Local Probe File (details)

On Windows 7 & 8 the local probe file is located at:

or on older versions of Windows:

where <user> is your logged in user name on your PC.

Delete this file to force the software to recreate it with correct information.

The Global Probe File (details)

There is another globally configurable probe file. This is unlikely to be corrupt but if you suspect it is, and you have adminstrator privileges on your PC to modify it, you can delete (or comment out) its contents (don't delete the file itself). It is highly unlikely you will need to do this but we mention it here as a last resort.

None of this works for you? Email us at support@bitscope.com for assistance!